TA1000-M1 Optical-Pumping Cesium Frequency Standard (Telecom)

TA1000-M1 Optical-Pumping Cesium Frequency Standard (Telecom)
Designed as first class time frequency standard for telecom industry, used as standard reference of synchronization core network, power grid industry, power telecommunication system.
Inquiry Now →

Application

Designed as first class time frequency standard for telecom industry, used as standard reference of synchronization core network, power grid industry, power telecommunication system.



Features

Adopt optical pump and detection technology;

Compact size, low power consumption,high reliability, and long service life;

Automatic monitoring operation status and recording;

Wide operating temperature range.


Main Specifications

Items

Specifications

Output signal

2 channels, 10MHz sine wave

2 channels, 5MHz sine wave

3 channels, 1PPS pulse signal

2 channels, 2048KHz/ E1, optional

Input signal

1 channel, 1PPS-SYNC

Size

19 inches, 4U racket (D 553mm±0.5 × L 456mm±0.5 × H177mm±0.5)

Weight

≤40kg (net weight)

Lock time

≤40min@20℃

Consumption

Warm up

≤200W@20℃

Steady state

≤120W@20℃

Power

AC

-48VDC, 2channels, redundant

10MHz

Output

7~13dBm (50Ω loading)

Frequency tolerance

≤±1E-12

Frequency stability

1s

≤1.2E-11

10s

≤8.5E-12

100s

≤2.7E-12

1000s

≤8.5E-13

10000s

≤2.7E-13

100000s

≤8.5E-14

Harmonic

≤-40dBc

Non-harmonic

≤-80dBc

Phase Noise (SSB)

1Hz

≤ - 100dBc

10Hz

≤ - 130dBc

100Hz

≤ - 145dBc

1000Hz

≤ - 150dBc

10KHz

≤ - 154dBc

100KHz

≤ - 154dBc

1PPS

Latitude

≥2.4V TTL (50Ω loading)

Pulse width

20μs

Rise time

≤10ns

Jitter

≤1ns

Synchronization accuracy

≤±20ns

2048KHz/E1

Interface performance

Meet up with GB/T 7611-2016 listed interface requirements

Signal specification

Meet up with (TU-TG.811 listed signal requirements)

E1 frame structure

Support SSM, meet up with GB/T7611-2016 listed frame structure requirements.

Repeatbility

≤5E-13

Frequency tuning range

≥1E-9

Resolution

≤1E-15

Operating temperature

0℃~40℃

Temperature coefficient

During full temperature range, frequency change is ≤1E-12

Storage temperature

-20℃~50℃

Air pressure sensitivity

≤5E-13/sea level 0~3KM

Magnetic sensitivity

≤1E-13 Gauss

Vibration

Meet up with 3rd class road condition, train transportation

EMC

Be in line with GJB151A naval ground condition

Service life

≥8years

MTBF

≥1000000hours

Interface port

BNC/TNC


Online Message

Submit

Related Suggestion